Video Views Creation and Modification |
Video presets and patterns enable users to perform automatic actions on domes. They are configured for view in the desktop dedicated to Video viewing. They enable to optimize the time dedicated to video viewing when displaying videos using pre-programmed views.
EntraPass enables users to define a wide variety of views, depending on their needs:
• Single camera
• Multiple cameras
• Multiple graphics and cameras
• Server-specific view: these are created by dragging a server into the display
• Multiple video servers: depending on their needs, EntraPass users can create views from multiple video servers.
Modifying a Video View
1 - From the Video view window, click the Modify Video view components button to edit or create content for the Video view desktop.
2 - From the left-hand panes, select a camera, a camera preset, or a camera pattern, then drag it into a right-hand pane cell. A camera is identified by its name and corresponding button. A preset is identified by the camera name and the preset name.
NOTE: A specific camera can appear in more than one cell; in this case, the Enable video sequence option must be enabled. A graphic can appear only in one cell.
NOTE: A Video view may only includes cameras of the same DVR type (HDVR, Intellex, TVR).
NOTE:
The
maximum number of TVR available is
3 - Select the camera layout you want by clicking on the corresponding button in the upper part of the right pane to specify the number of images you want to display:
• Click 1 X 1 to display 1 image
• Click 2 X 2 to display 4 images
• Click 3 X 3 to display 9 images
• Click 4 X 4 to display 16 images.
NOTE: You can create a view by dragging a video server into the display. This view will contain all cameras from this specific server.
NOTE: The number of images displayed influence the speed of the network bandwidth. For example, if you are displaying 4X4 images, the network bandwidth will be slower than when you are displaying a 1X1 image.
4 - Click the Test button to view the result of the selection. The displayed Video view appears in the Video desktop for video monitoring and surveillance ( Desktops > Desktop dedicated to video monitoring).
NOTE: To delete a camera from a cell, right-click it, then select Delete from the shortcut menu.
5 - Click the Close button (bottom left or the “X” top right) to close the Video test window.